Detail Information |
|||
| Name: | Laboratory Vacuum Furnace | Cooling: | Water |
|---|---|---|---|
| Color: | White | Melting Material: | Various Metal |
| Usage: | Melting Furnace | Dimension(L*W*H): | Custom Made |
| Highlight: | vacuum melting furnace,vacuum heat treatment furnace |
||
Product Description
Industrial Vacuum Induction Melting Furnace With Water Cooling System
1) Simple structure with compact design for less space.
2) Adopting advanced world famous brand components.
3) Advanced medium frequency power supply.
4) Full protective measurements for safe and reliable operation.
5) Energy saving.
6) Less burning loss.
7) Quick heating and melting speed.
This vacuum induction melting furnace is widely used for smelting and precise casting for iron-based, nickel-based, high temperature alloy and other precise alloy as well as magnetic materials.
| Volume (L) | 192 | 350 | 484 | 1920 |
| Rated Temperature (°C) | 2400 | 2400 | 2400 | 2400 |
| Limit Temperature (°C) | 2450 | 2450 | 2450 | 2450 |
| Effective Heating Zone (Mm) | 400X400X1200 | 500X500X1400 | 550X550X1600 | 800X800X3000 |
| Power (KW) | 150 | 250 | 350 | 550 |
| Frequency (HZ) | 1500 | 1000 | 1000 | 1000 |
| Temperature Control Method | Japanese island electric thermostat | |||
| Heating Method | Induction heating | |||
| Vacuum System | Spool valve vacuum pump + Roots vacuum pump | |||
| Sintering Atmosphere | N2, Ar2 and other gases | |||
| Rated Power Supply Voltage (V) | 380 | |||
| Rated Heating Voltage (V) | According to the design, configure the transformer | |||
| Vacuum Limit (Pa) | 40 (vacuum cold state) | |||